ORA-03113 ERROR after shutdown abort(incomplete shutdown)

if you got error ORA-03114 like this

Snip20141228 1

you can simply try to fix by following commands
1.)
go to service.msc, restart the service of the instance
2.)
after restart the service.
should be able to get in by sqlplus as sysdba
then,

shutdown abort
exit

3.)
re-login sqlplus as sysdba

startup mount
recover database 
until time '2014-12-27 0:00:00'; -- TODAY's DATE
alter database open resetlogs;
shutdown;
startup;

that’s it!

good luck!